Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 286
Filter
1.
J. bras. nefrol ; 46(2): e2024PO02, Apr.-June 2024.
Article in English | LILACS-Express | LILACS | ID: biblio-1550492

ABSTRACT

ABSTRACT The desperate attempt to improve mortality, morbidity, quality of life and patient-reported outcomes in patients on hemodialysis has led to multiple attempts to improve the different modes, frequencies, and durations of dialysis sessions in the last few decades. Nothing has been more appealing than the combination of diffusion and convection in the form of hemodiafiltration. Despite the concrete evidence of better clearance of middle weight molecules and better hemodynamic stability, tangible evidence to support the universal adoption is still at a distance. Survival benefits seen in selected groups who are likely to tolerate hemodiafiltration with better vascular access and with lower comorbid burden, need to be extended to real life dialysis patients who are older than the population studied and have significantly higher comorbid burden. Technical demands of initiation hemodiafiltration, the associated costs, and the incremental benefits targeted, along with patient-reported outcomes, need to be explored further before recommending hemodiafiltration as the mode of choice.


RESUMO A tentativa desesperada de melhorar a mortalidade, morbidade, qualidade de vida e desfechos relatados pelos pacientes em indivíduos em hemodiálise levou a diversas tentativas de aprimorar os diferentes modos, frequências e durações das sessões de diálise nas últimas décadas. Nada foi mais atrativo do que a combinação de difusão e convecção na forma de hemodiafiltração. Apesar das evidências concretas de melhor depuração de moléculas de peso médio e melhor estabilidade hemodinâmica, evidências tangíveis para apoiar a adoção universal ainda estão distantes. Os benefícios de sobrevida observados em grupos selecionados que provavelmente toleram a hemodiafiltração com melhor acesso vascular e com menor carga de comorbidades precisam ser estendidos aos pacientes reais em diálise, que são mais velhos do que a população estudada e apresentam uma carga de comorbidades significativamente maior. As exigências técnicas do início da hemodiafiltração, os custos associados e os benefícios incrementais almejados, juntamente com os desfechos relatados pelos pacientes, precisam ser melhor explorados antes de se recomendar a hemodiafiltração como o modo de escolha.

2.
Braz. j. biol ; 84: e254010, 2024. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1345561

ABSTRACT

Abstract The impact of fish oil concentration on the oxidative stability of microcapsules through the spray drying process using chitosan and maltodextrin as wall material was studied. Emulsions were prepared with different Tuna fish oil (TFO) content (TFO-10%, TFO20%, TF030% TF0-40%) while wall material concentration was kept constant. Microencapsulated powder resulting from emulsion prepared with high fish oil load have high moisture content, wettability, total oil and low encapsulation efficiency, hygroscopicity and bulk tapped density. Oxidative stability was evaluated periodically by placing microcapsules at room temperature. Microcapsules prepared with TFO-10% presented high oxidative stability in terms of peroxide value (2.94±0.04) and anisidine value (1.54±0.02) after 30 days of storage. It was concluded that optimal amounts of fish oil for microencapsulation are 10% and 20% using chitosan and maltodextrin that extended its shelf life during study period.


Resumo Foi estudado o impacto da concentração de óleo de peixe na estabilidade oxidativa de microcápsulas por meio do processo de secagem por atomização, utilizando quitosana e maltodextrina como material de parede. As emulsões foram preparadas com diferentes teores de óleo de atum (TFO) (TFO-10%, TFO20%, TF030% TF0-40%), enquanto a concentração de material de parede foi mantida constante. O pó microencapsulado resultante da emulsão preparada com alta carga de óleo de peixe tem alto teor de umidade, molhabilidade e óleo total e baixa eficiência de encapsulação, higroscopicidade e densidade extraída a granel. A estabilidade oxidativa foi avaliada periodicamente colocando microcápsulas à temperatura ambiente. As microcápsulas preparadas com TFO-10% apresentaram alta estabilidade oxidativa em termos de valor de peróxido (2,94 ± 0,04) e valor de anisidina (1,54 ± 0,02) após 30 dias de armazenamento. Concluiu-se que as quantidades ideais de óleo de peixe para microencapsulação são de 10% e 20% usando quitosana e maltodextrina que prolongaram sua vida útil durante o período de estudo.


Subject(s)
Animals , Fish Oils , Chitosan , Powders , Tuna , Oxidative Stress
3.
Braz. j. biol ; 84: e255235, 2024. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1355897

ABSTRACT

Abstract In soybean breeding program, continuous selection pressure on traits response to yield created a genetic bottleneck for improvements of soybean through hybridization breeding technique. Therefore an initiative was taken to developed high yielding soybean variety applying mutation breeding techniques at Plant Breeding Division, Bangladesh Institute of Nuclear Agriculture (BINA), Bangladesh. Locally available popular cultivar BARI Soybean-5 was used as a parent material and subjected to five different doses of Gamma ray using Co60. In respect to seed yield and yield attributing characters, twelve true breed mutants were selected from M4 generation. High values of heritability and genetic advance with high genotypic coefficient of variance (GCV) for plant height, branch number and pod number were considered as favorable attributes for soybean improvement that ensure expected yield. The mutant SBM-18 obtained from 250Gy provided stable yield performance at diversified environments. It provided maximum seed yield of 3056 kg ha-1 with highest number of pods plant-1 (56). The National Seed Board of Bangladesh (NSB) eventually approved SBM-18 and registered it as a new soybean variety named 'Binasoybean-5' for large-scale planting because of its superior stability in various agro-ecological zones and consistent yield performance.


Resumo No programa de melhoramento da soja, a pressão pela seleção contínua para a resposta das características de rendimento criou um gargalo genético para melhorias da soja por meio da técnica de melhoramento por hibridação. Portanto, foi desenvolvida uma variedade de soja de alto rendimento, aplicando técnicas de reprodução por mutação, na Divisão de Melhoramento de Plantas, no Instituto de Agricultura Nuclear de Bangladesh (BINA), em Bangladesh. A cultivar popular BARI Soybean-5, disponível localmente, foi usada como material original e submetida a cinco doses diferentes de raios gama usando Co60. Em relação ao rendimento de sementes e às características de atribuição de rendimento, 12 mutantes genuínos foram selecionados a partir da geração M4. Altos valores de herdabilidade e avanço genético com alto coeficiente de variância genotípico (GCV) para altura da planta, número de ramos e número de vagens foram considerados atributos favoráveis ​​ao melhoramento da soja, garantindo, assim, a produtividade esperada. O mutante SBM-18, obtido a partir de 250Gy, proporcionou desempenho de rendimento estável em ambientes diversificados e produtividade máxima de sementes de 3.056 kg ha-1 com o maior número de vagens planta-1 (56). O Conselho Nacional de Sementes de Bangladesh (NSB) finalmente aprovou o SBM-18 e o registrou como uma nova variedade de soja, chamada 'Binasoybean-5', para plantio em larga escala por causa de sua estabilidade superior em várias zonas agroecológicas e desempenho de rendimento consistente.


Subject(s)
Soybeans/growth & development , Soybeans/genetics , Phenotype , Bangladesh , Plant Breeding , Genotype , Mutation
4.
Braz. j. biol ; 842024.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469256

ABSTRACT

Abstract The impact of fish oil concentration on the oxidative stability of microcapsules through the spray drying process using chitosan and maltodextrin as wall material was studied. Emulsions were prepared with different Tuna fish oil (TFO) content (TFO-10%, TFO20%, TF030% TF0-40%) while wall material concentration was kept constant. Microencapsulated powder resulting from emulsion prepared with high fish oil load have high moisture content, wettability, total oil and low encapsulation efficiency, hygroscopicity and bulk tapped density. Oxidative stability was evaluated periodically by placing microcapsules at room temperature. Microcapsules prepared with TFO-10% presented high oxidative stability in terms of peroxide value (2.94±0.04) and anisidine value (1.54±0.02) after 30 days of storage. It was concluded that optimal amounts of fish oil for microencapsulation are 10% and 20% using chitosan and maltodextrin that extended its shelf life during study period.


Resumo Foi estudado o impacto da concentração de óleo de peixe na estabilidade oxidativa de microcápsulas por meio do processo de secagem por atomização, utilizando quitosana e maltodextrina como material de parede. As emulsões foram preparadas com diferentes teores de óleo de atum (TFO) (TFO-10%, TFO20%, TF030% TF0-40%), enquanto a concentração de material de parede foi mantida constante. O pó microencapsulado resultante da emulsão preparada com alta carga de óleo de peixe tem alto teor de umidade, molhabilidade e óleo total e baixa eficiência de encapsulação, higroscopicidade e densidade extraída a granel. A estabilidade oxidativa foi avaliada periodicamente colocando microcápsulas à temperatura ambiente. As microcápsulas preparadas com TFO-10% apresentaram alta estabilidade oxidativa em termos de valor de peróxido (2,94 ± 0,04) e valor de anisidina (1,54 ± 0,02) após 30 dias de armazenamento. Concluiu-se que as quantidades ideais de óleo de peixe para microencapsulação são de 10% e 20% usando quitosana e maltodextrina que prolongaram sua vida útil durante o período de estudo.

5.
Braz. j. biol ; 842024.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469302

ABSTRACT

Abstract In soybean breeding program, continuous selection pressure on traits response to yield created a genetic bottleneck for improvements of soybean through hybridization breeding technique. Therefore an initiative was taken to developed high yielding soybean variety applying mutation breeding techniques at Plant Breeding Division, Bangladesh Institute of Nuclear Agriculture (BINA), Bangladesh. Locally available popular cultivar BARI Soybean-5 was used as a parent material and subjected to five different doses of Gamma ray using Co60. In respect to seed yield and yield attributing characters, twelve true breed mutants were selected from M4 generation. High values of heritability and genetic advance with high genotypic coefficient of variance (GCV) for plant height, branch number and pod number were considered as favorable attributes for soybean improvement that ensure expected yield. The mutant SBM-18 obtained from 250Gy provided stable yield performance at diversified environments. It provided maximum seed yield of 3056 kg ha-1 with highest number of pods plant-1 (56). The National Seed Board of Bangladesh (NSB) eventually approved SBM-18 and registered it as a new soybean variety named Binasoybean-5 for large-scale planting because of its superior stability in various agro-ecological zones and consistent yield performance.


Resumo No programa de melhoramento da soja, a pressão pela seleção contínua para a resposta das características de rendimento criou um gargalo genético para melhorias da soja por meio da técnica de melhoramento por hibridação. Portanto, foi desenvolvida uma variedade de soja de alto rendimento, aplicando técnicas de reprodução por mutação, na Divisão de Melhoramento de Plantas, no Instituto de Agricultura Nuclear de Bangladesh (BINA), em Bangladesh. A cultivar popular BARI Soybean-5, disponível localmente, foi usada como material original e submetida a cinco doses diferentes de raios gama usando Co60. Em relação ao rendimento de sementes e às características de atribuição de rendimento, 12 mutantes genuínos foram selecionados a partir da geração M4. Altos valores de herdabilidade e avanço genético com alto coeficiente de variância genotípico (GCV) para altura da planta, número de ramos e número de vagens foram considerados atributos favoráveis ao melhoramento da soja, garantindo, assim, a produtividade esperada. O mutante SBM-18, obtido a partir de 250Gy, proporcionou desempenho de rendimento estável em ambientes diversificados e produtividade máxima de sementes de 3.056 kg ha-1 com o maior número de vagens planta-1 (56). O Conselho Nacional de Sementes de Bangladesh (NSB) finalmente aprovou o SBM-18 e o registrou como uma nova variedade de soja, chamada Binasoybean-5, para plantio em larga escala por causa de sua estabilidade superior em várias zonas agroecológicas e desempenho de rendimento consistente.

6.
Rev. Flum. Odontol. (Online) ; 1(60): 112-126, jan.-abr. 2023. tab
Article in Portuguese | LILACS, BBO | ID: biblio-1411346

ABSTRACT

A descoloração ou perda de translucidez dos materiais cerâmicos usados em odontologia ainda hoje é um problema, especialmente pelo comprometimento estético. Com o objetivo de comparar a estabilidade de cor, blocos de dissilicato de lítio (IPS e.max CAD HT) e de silicato de lítio reforçado com zircônia (Vita Suprinity HT) fresados no desenho de um disco com dimensões de 1,5 × 7 × 12 mm3 (n = 120) foram preparados usando 3 procedimentos de acabamento de superfície: glaze, polimento mecânico e coloração externa e glaze. Em seguida, cada grupo foi dividido em 2 subgrupos de armazenamento, chá preto e café (n = 10/grupo). As mensurações de cor foram medidas com espectrofotômetro (VITA Easyshade) no estágio inicial e após 1 semana, 2 semanas, 1 mês, 2 meses de armazenamento. As alterações de cor (ΔE) foram calculadas e analisadas estatisticamente usando ANOVA (α < 0,05). Observamos que, para ambos os materiais cerâmicos, o procedimento de glaze apresentou valores de mudança de cor estatisticamente menores do que os outros grupos (p < 0,05) após o armazenamento em ambas as bebidas. Os grupos de dissilicato de lítio apresentaram valores de alteração de cor estatisticamente menores em relação aos grupos de silicato de lítio reforçados com zircônia. Conclui-se que, o glaze sozinho levou a uma maior estabilidade de cor em relação ao polimento mecânico e coloração externa o dissilicato de lítio apresentou maior estabilidade de cor em comparação com o silicato de lítio reforçada com zircônia.


The discoloration or loss of translucency of ceramic materials used in dentistry is still a problem today, especially due to aesthetic compromise. In order to compare color stability, lithium disilicate (IPS e.max CAD HT) and zirconia-reinforced lithium silicate (Vita Suprinity HT) blocks were milled into a disc design with dimensions of 1.5 × 7 × 12 mm3 (n = 120). The specimens were prepared using 3 surface finishing procedures: glaze, mechanical polishing and external staining and glaze. Then, each group was divided into 2 storage subgroups, black tea and coffee (n = 10/group). Color measurements were measured with a spectrophotometer (VITA Easyshade) at the initial stage and after 1 week, 2 weeks, 1 month, 2 months of storage. Color changes (ΔE) were calculated and statistically analyzed using ANOVA (α < 0.05). We observed that, for both ceramic materials, the glaze procedure presented statistically lower color change values ​​than the other groups (p < 0.05) after storage in both beverages. The lithium disilicate groups showed statistically lower color change values ​​than the zirconia-reinforced lithium silicate groups. It is concluded that, glaze alone led to greater color stability compared to mechanical polishing and external staining, lithium disilicate showed greater color stability compared to zirconia-reinforced lithium silicate.


Subject(s)
Beverages , Ceramics , Computer-Aided Design , Color , Dental Polishing/methods , Lithium , Silicates
7.
Arq. ciências saúde UNIPAR ; 27(5): 2729-2744, 2023.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1435009

ABSTRACT

O azeite de oliva é amplamente consumido devido às suas propriedades benéficas para a saúde e características sensoriais únicas. A composição química abundante em ácido graxo monoinsaturado, associada ao perfil de compostos fenólicos com importante efeito antioxidante, confere ao azeite de oliva alta estabilidade ao aquecimento. Embora existam muitas evidências sobre a estabilidade térmica do azeite, ainda existem muitas dúvidas, por parte da população, sobre o uso em técnicas culinárias que envolvam calor. O objetivo desse trabalho foi compilar evidências científicas a respeito da influência de técnicas culinárias sobre a estabilidade térmica do azeite de oliva, com vistas a elaborar material informativo, com linguagem adaptada à população em geral, sobre sua utilização na culinária, especialmente em preparações quentes. É de amplo conhecimento na literatura que o azeite de oliva é bastante resistente à cocção, no entanto, temperaturas elevadas, como as empregadas na fritura por imersão, podem levar a diminuição do teor de compostos fenólicos, a depender da quantidade e tipos de fenólicos presentes no azeite. Estudos no contexto da gastronomia molecular também relatam, além da estabilidade térmica, os benefícios da utilização do azeite de oliva na culinária devido às interações químicas entre os compostos do azeite e os compostos do alimento fazendo com que ambos (óleo e alimentos) se beneficiem dos efeitos protetivos desses compostos. Considerando que ainda é muito comum o uso do azeite de oliva apenas para temperar saladas e finalizar pratos, o infográfico elaborado no presente trabalho pode contribuir para apresentar o conteúdo científico sobre o uso do azeite em preparações culinárias quentes de forma simplificada e de fácil compreensão.


Olive oil is widely consumed due to its beneficial health properties and unique sensory characteristics. The chemical composition abundant in monounsaturated fatty acids, associated with a profile of phenolic compounds with important antioxidant effects, gives olive oil high heat stability. Although there is much evidence about the thermal stability of olive oil, there are still many doubts among the population about its use in cooking techniques that involve heat. The objective of this work was to compile scientific evidence about the influence of cooking techniques on the thermal stability of olive oil, in order to elaborate informative material, with language adapted to the general population, about its use in cooking, especially in hot preparations. It is widely known in the literature that olive oil is very resistant to cooking, however, high temperatures, such as those used in deep frying, can lead to a decrease in the content of phenolic compounds, depending on the amount and types of phenolics present in the oil. Studies in the context of molecular gastronomy also report, besides thermal stability, the benefits of using olive oil in cooking due to chemical interactions between the compounds of olive oil and food compounds, so that both (oil and food) benefit from the protective effects of these compounds. Considering that it is still very common to use olive oil only to season salads and finish dishes, the infographic prepared in this work can contribute to present the scientific content about the use of olive oil in hot culinary preparations in a simplified and easy to understand way.


El aceite de oliva es ampliamente consumido por sus propiedades beneficiosas para la salud y sus características sensoriales únicas. La composición química abundante en ácidos grasos monoinsaturados, asociada al perfil de compuestos fenólicos con importante efecto antioxidante, confiere al aceite de oliva una gran estabilidad al calentamiento. Aunque hay muchas evidencias sobre la estabilidad térmica del aceite de oliva, todavía existen muchas dudas entre la población sobre su uso en técnicas culinarias que implican calor. El objetivo de este trabajo fue recopilar evidencias científicas sobre la influencia de las técnicas culinarias en la estabilidad térmica del aceite de oliva, con el fin de elaborar material divulgativo, con lenguaje adaptado a la población general, sobre su uso en cocina, especialmente en preparaciones calientes. Es ampliamente conocido en la literatura que el aceite de oliva es bastante resistente a la cocción, sin embargo, las altas temperaturas, como las empleadas en la fritura por inmersión, pueden llevar a disminuir el contenido de compuestos fenólicos, dependiendo de la cantidad y tipos de fenólicos presentes en el aceite. Los estudios en el contexto de la gastronomía molecular también informan, además de la estabilidad térmica, de los beneficios del uso del aceite de oliva en la cocina debido a las interacciones químicas entre los compuestos del aceite de oliva y los compuestos de los alimentos, de forma que ambos (aceite y alimento) se benefician de los efectos protectores de estos compuestos. Teniendo en cuenta que todavía es muy común el uso del aceite de oliva sólo para aliñar ensaladas y terminar platos, la infografía elaborada en este trabajo puede contribuir a presentar de forma simplificada y fácil de entender el contenido científico sobre el uso del aceite de oliva en preparaciones culinarias calientes.

8.
São Paulo; s.n; s.n; 2023. 103 p. tab, graf.
Thesis in Portuguese | LILACS | ID: biblio-1437866

ABSTRACT

O objetivo geral desse trabalho foi desenvolver compostos de coordenação com os metais cobre, manganês, zinco, cobalto, níquel e magnésio com os aminoácidos L- ácido aspártico e glutâmico para aplicação como fertilizantes foliares e elucidação de seus prováveis mecanismos de absorção pela planta. Como plano de trabalho, pretendeu-se produzir alguns complexos metálicos com agentes complexantes que confiram características específicas: alta estabilidade termodinâmica e cinética quando comparado a quelatos usados comercialmente dos mesmos metais; alta solubilidade; compatibilidade com herbicidas e fungicidas e alta estabilidade frente a variações de pH. Os compostos foram caracterizados no estado sólido e/ou em solução aquosa, através de técnicas disponíveis em nosso laboratório, na Central Analítica do IQ-USP e/ou nos laboratórios da ICL América do Sul Ind. e Com. SA. Com o desenvolvimento dos compostos de coordenação, foram avaliados alguns parâmetros considerados imprescindíveis para garantia da qualidade do produto gerado, que foram então comparados aos de quelatos de EDTA (ácido etilenodiaminotetraacético) comercializados atualmente e que demonstraram vantagens. Para avaliar a eficiência dos produtos gerados foi realizada aplicação foliar em ao menos uma cultura e verificado o teor de cada nutriente após período de absorção e resposta produtiva, evidenciando e determinando o mecanismo de absorção realizado pela planta. Como resultado, desenvolveu-se uma série de produtos com alta tecnologia agregada que trouxeram benefícios nutricionais, sustentando uma nutrição de qualidade além de serem ecologicamente favoráveis (eco-friendly portfolio)


This project aims the development of copper, manganese, zinc, cobalt, nickel and iron metal complexes with L-amino acids aspartic and glutamic acids for application as foliar fertilizers and elucidation of the probable incorporation/absorption mechanism by plants. As a work plan, it was intended to produce these metal complexes with complexing agents that provide specific characteristics: high thermodynamic and kinetic stabilities when compared to the corresponding EDTA chelates; high solubility; compatibility with herbicides and fungicides and high stability against pH variations. With the development of such coordination compounds, some parameters considered indispensable to quality assurance were then evaluated, in comparison to that of currently available commercial EDTA chelates. To evaluate the performance of the obtained compounds, two foliar applications in the same crop were carried out. Further, the content of each nutrient after the production period and the productive capacity were evaluated, aiming to elucidate the absorption mechanism of the plant. As a result, elaborated products with high added technology were obtained, capable of ameliorating the nutritional benefits, that can support an eco-friendly portfolio


Subject(s)
Absorption , Coordination Complexes/analysis , Cobalt/agonists , Copper/agonists , Iron/agonists
9.
Dental press j. orthod. (Impr.) ; 28(2): e2321345, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1439988

ABSTRACT

ABSTRACT Objectives: This clinical trial was conducted to evaluate the stability and failure rate of surface-treated orthodontic mini-implants and determine whether they differ from those of non-surface-treated orthodontic mini-implants. Trial Design: Randomized clinical trial with a split-mouth study design. Setting: Department of Orthodontics, SRM Dental College, Chennai. Participants: Patients who required orthodontic mini-implants for anterior retraction in both arches. Methods: Self-drilling, tapered, titanium orthodontic mini-implants with and without surface treatment were placed in each patient following a split-mouth design. The maximum insertion and removal torques were measured for each implant using a digital torque driver. The failure rates were calculated for each type of mini-implant. Results: The mean maximum insertion torque was 17.9 ± 5.6 Ncm for surface-treated mini-implants and 16.4 ± 9.0 Ncm for non-surface-treated mini-implants. The mean maximum removal torque was 8.1 ± 2.9 Ncm for surface-treated mini-implants and 3.3 ± 1.9 Ncm for non-surface-treated mini-implants. Among the failed implants, 71.4% were non-surface-treated mini-implants and 28.6% were surface-treated mini-implants. Conclusion: The insertion torque and failure rate did not differ significantly between the groups, whereas the removal torque was significantly higher in the surface-treated group. Thus, surface treatment using sandblasting and acid etching may improve the secondary stability of self-drilling orthodontic mini-implants. Trial registration: The trial was registered in the Clinical Trials Registry, India (ICMR NIMS). Registration number: CTRI/2019/10/021718


RESUMO Objetivos: Este ensaio clínico foi conduzido para avaliar a estabilidade e a taxa de falha de mini-implantes ortodônticos com superfície tratada, e determinar se elas diferem das dos mini-implantes ortodônticos sem superfície tratada. Desenho do estudo: Ensaio clínico randomizado com desenho de boca dividida. Instituição: Department of Orthodontics, SRM Dental College, Chennai/India. Participantes: Pacientes que necessitavam de mini-implantes ortodônticos para retração anterior em ambas as arcadas. Métodos: Mini-implantes ortodônticos autoperfurantes, cônicos, de titânio com ou sem tratamento de superfície, foram colocados em cada paciente, seguindo um desenho de boca dividida. Os torques máximos de inserção e de remoção foram medidos para cada mini-implante, usando um torquímetro digital. As taxas de falha foram calculadas para cada tipo de mini-implante. Resultados: O valor médio do torque máximo de inserção foi de 17,9 ± 5,6 Ncm para mini-implantes com superfície tratada e 16,4 ± 9,0 Ncm para mini-implantes sem superfície tratada. O valor médio do torque máximo de remoção foi de 8,1 ± 2,9 Ncm para mini-implantes com superfície tratada e 3,3 ± 1,9 Ncm para mini-implantes sem superfície tratada. Entre os implantes que falharam, 71,4% eram mini-implantes sem superfície tratada e 28,6% eram mini-implantes com superfície tratada. Conclusão: O torque de inserção e a taxa de falha não diferiram significativamente entre os grupos; porém, o torque de remoção foi significativamente maior no grupo com superfície tratada. Assim, o tratamento de superfície com jateamento e condicionamento ácido pode melhorar a estabilidade secundária dos mini-implantes ortodônticos autoperfurantes. Registro do estudo: Esse estudo foi registrado no Clinical Trials Registry, Índia (ICMR NIMS). Número de registro: CTRI/2019/10/021718

10.
Rev. bras. med. esporte ; 29: e2022_0327, 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1407587

ABSTRACT

ABSTRACT Introduction: Physical confrontation in soccer games presents greater demands on athletes' physical fitness. A soccer player's speed, strength, flexibility, coordination, endurance, and explosiveness can affect the body's fighting capacity. Objective: This study analyzes the relationship between strength training in soccer players' abdominal core and physical fitness. Methods: The effect of abdominal core stability strength training on performance improvement in volunteer soccer players selected as research subjects was verified by random division into two groups (experimental and control groups). Both groups performed daily training. The experimental group added special abdominal core training. Mathematical-statistical algorithms were used to statistically analyze the physical indicators of the two groups of volunteers. Results: The indices of physical fitness and body explosiveness of the two groups of athletes were significantly improved (P<0.05). After systematic training, the competition performance of the experimental group and the physiological and biochemical indicators were better than the control group (P<0.05). Conclusion: After abdominal core training, soccer players' physical fitness and explosive power indexes were improved. Research shows that strength training can help improve abdominal core performance in soccer players. It is recommended that coaches implement abdominal core strength training in the daily training of athletes. Level of evidence II; Therapeutic studies - investigation of treatment outcomes.


RESUMO Introdução: O confronto físico nos jogos de futebol apresenta maiores exigências quanto à aptidão física dos atletas. A velocidade, força, flexibilidade, coordenação, resistência e explosividade de um jogador de futebol podem afetar a capacidade de combate corporal. Objetivo: Este estudo visa analisar a relação entre o treinamento de força no core abdominal dos jogadores de futebol e sua aptidão física. Métodos: O efeito do treinamento de força da estabilidade do core abdominal sobre a melhoria do desempenho nos jogadores de futebol voluntários selecionados como objetos de pesquisa foi verificado por divisão aleatória em dois grupos (grupos experimentais e grupos de controle). Ambos os grupos realizavam treinamentos diários. O grupo experimental acrescentou treinamento especial de core abdominal. Foram utilizados algoritmos matemáticos-estatísticos para analisar os indicadores físicos dos dois grupos de voluntários de forma estatística. Resultados: Os índices de aptidão física e explosividade corporal dos dois grupos de atletas foram significativamente melhorados (P<0,05). Após o treinamento sistemático, o desempenho de competição do grupo experimental e os indicadores fisiológicos e bioquímicos foram melhores que os do grupo de controle (P<0,05). Conclusão: Após o treinamento do core abdominal, a aptidão física dos jogadores de futebol e os índices de potência explosiva foram melhorados. Pesquisas mostram que o treinamento da força pode ajudar a melhorar o desempenho do core abdominal nos jogadores de futebol. Recomenda-se aos treinadores a implementação do treino de força no core abdominal ao treinamento diário dos atletas. Nível de evidência II; Estudos terapêuticos - investigação dos resultados do tratamento.


RESUMEN Introducción: El enfrentamiento físico en los partidos de fútbol presenta mayores exigencias a la aptitud física de los atletas. La velocidad, la fuerza, la flexibilidad, la coordinación, la resistencia y la explosividad de un jugador de fútbol pueden afectar a la capacidad de combate del cuerpo. Objetivo: Este estudio tiene como objetivo analizar la relación entre el entrenamiento de la fuerza en el core de los jugadores de fútbol y su condición física. Métodos: El efecto del entrenamiento de la fuerza de la estabilidad del core abdominal sobre la mejora del rendimiento en jugadores de fútbol voluntarios seleccionados como sujetos de la investigación se verificó mediante la división aleatoria en dos grupos (grupo experimental y grupo de control). Ambos grupos realizaron un entrenamiento diario. El grupo experimental añadió un entrenamiento especial del core abdominal. Se utilizaron algoritmos matemático-estadísticos para analizar de forma estadística los indicadores físicos de los dos grupos de voluntarios. Resultados: Los índices de aptitud física y explosividad corporal de los dos grupos de atletas mejoraron significativamente (P<0,05). Tras el entrenamiento sistemático, el rendimiento en competición del grupo experimental y los indicadores fisiológicos y bioquímicos fueron mejores que los del grupo de control (P<0,05). Conclusión: Tras el entrenamiento del core abdominal, mejoraron la condición física y los índices de potencia explosiva de los futbolistas. Las investigaciones demuestran que el entrenamiento de fuerza puede ayudar a mejorar el rendimiento del core abdominal en los jugadores de fútbol. Se recomienda que los entrenadores implementen el entrenamiento de fuerza en el core abdominal al entrenamiento diario de los atletas. Nivel de evidencia II; Estudios terapéuticos - investigación de los resultados del tratamiento.

11.
Braz. dent. sci ; 26(4): 1-12, 2023. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-1519603

ABSTRACT

ABSTRACT Objective: The aim of this study is to determine the effect of Advanced Platelet-Rich Fibrin on bone density and implant stability in immediately loaded- implant-assisted mandibular overdentures (Split-mouth study). Material and Methods: Ten completely edentulous patients received two implants in the mandibular canine region and locator attachments were used to retain immediately loaded- implant mandibular overdentures. Each patient served in two Groups, one Group for each side. One side of the mandible received an implant with topical application of Advanced Platelet-Rich Fibrin in the implant osteotomy site (Group I) and the other site received an implant without application of Advanced platelet-rich fibrin (Group II). Each patient was examined clinically for implant stability using Osstell Mentor device and radiographically by ultra-low dose CT scan to measure bone density around the implant at baseline, three, six months, and one year. Results: There were no statistically significant differences (P>.05) in bone density and implant stability among the studied Groups during one year follow-up period. Conclusion : Advanced Platelet-Rich Fibrin has no effect on bone density and implant stability in immediately loaded implant-assisted mandibular overdenture.(AU)


RESUMO Objetivo: O objetivo deste estudo é determinar o efeito da Fibrina Rica em Plaquetas Avançada na densidade óssea e estabilidade dos implantes em Overdentures mandibulares com carga imediata (estudo de boca dividida). Material e Métodos: Dez pacientes edêntulos foram submetidos à instalação de dois implantes mandibulares na região dos caninos e pilares locator foram utilizados como sistema de retenção para as overdentures mandibulares com carga imediata. Cada paciente participou nos dois grupos, sendo um grupo para cada lado. Um lado da mandíbula recebeu implante com aplicação tópica de Fibrina Rica em Plaquetas Avançada no local do sítio cirúrgico do implante (Grupo I) e o outro local recebeu implante sem aplicação de Fibrina Rica em Plaquetas Avançada (Grupo II). Cada paciente foi examinado clinicamente quanto à estabilidade do implante usando o dispositivo Osstell Mentor e radiograficamente por tomografia computadorizada de ultrabaixa dose para medir a densidade óssea ao redor do implante no início do estudo, três, seis meses e um ano. Resultados: Não houve diferenças estatisticamente significativas (P>0,05) na densidade óssea e na estabilidade do implante entre os grupos estudados durante o período de acompanhamento de um ano. Conclusão: A Fibrina Rica em Plaquetas Avançada não tem efeito na densidade óssea e na estabilidade de implantes em Overdentures mandibulares com carga imediata (AU)


Subject(s)
Humans , Middle Aged , Bone Density/drug effects , Denture, Overlay , Immediate Dental Implant Loading , Mandibular Osteotomy , Platelet-Rich Fibrin/chemistry , Radiography , Double-Blind Method , Cuspid/surgery , Mandible/diagnostic imaging
12.
Rev. bras. med. esporte ; 29: e2022_0304, 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1407635

ABSTRACT

ABSTRACT Introduction: Physical conditioning is an essential component of sports skills. The main routine training methods for skill enhancement in martial arts players should be based on traditional movements. Core strength training has also been shown to be valid for the physical conditioning of martial arts players. Objective: This paper studies the qualitative changes in the balance of martial arts athletes caused by the insertion of core strength training. Methods: This paper selects 24 martial arts players by sampling and randomly divides them into control and experimental groups. The biomarkers of the volunteers were stored and processed under statistical methods to organize and display the data. Results: The experimental and control groups showed high statistical significance in each index after testing (P<0.05). The results show that the methods used in the experimental and control groups can effectively improve their performance in core and key explosive movements during exercise. There were very significant changes in the extensor muscle peak in both groups. The experimental group showed more significant improvement than the standard group (P<0.05). The experimental group's flexor peaks showed a more significant difference than the control group. In contrast, the experimental group showed a more remarkable improvement than the standard group (P<0.05). Conclusion: Core resistance exercise can effectively promote a center of gravity balance in martial arts athletes. Level of evidence II; Therapeutic studies - investigation of treatment outcomes.


RESUMO Introdução: O condicionamento físico é um componente essencial das habilidades esportivas. Os principais métodos de treino de rotina para aumento da habilidade dos jogadores de artes marciais devem ser baseados em movimentos tradicionais. O treinamento de resistência do core também já se mostrou válido sobre o condicionamento físico dos jogadores de artes marciais. Objetivo: Este artigo estuda as alterações qualitativas sobre o equilíbrio dos atletas de artes marciais provocadas pela inserção do treino de resistência do core. Métodos: Este artigo seleciona 24 jogadores de artes marciais por amostragem e os divide aleatoriamente em grupos controle e experimental. Os biomarcadores dos voluntários foram armazenados e processados sob métodos estatísticos para organizar e exibir os dados. Resultados: Os grupos experimentais e de controle apresentaram alta significância estatística em cada índice após o teste (P<0,05). Os resultados mostram que os métodos utilizados nos grupos experimentais e de controle podem melhorar efetivamente seu desempenho no core e nos principais movimentos explosivos durante o exercício. Houveram mudanças muito significativas no pico dos músculos extensores em ambos os grupos. O grupo experimental apresentou melhora mais significativa do que o grupo padrão (P<0,05). Em comparação com o grupo controle, os picos de flexores do grupo experimental apresentaram uma diferença mais significativa. Em contrapartida, o grupo experimental apresentou uma melhora mais notável do que o grupo padrão (P<0,05). Conclusão: O exercício de resistência do core pode efetivamente promover a equilíbrio do centro de gravidade nos atletas de artes marciais. Nível de evidência II; Estudos terapêuticos - investigação dos resultados do tratamento.


RESUMEN Introducción: El acondicionamiento físico es un componente esencial de las habilidades deportivas. Los principales métodos de entrenamiento rutinario para aumentar la capacidad de los jugadores de artes marciales deben basarse en los movimientos tradicionales. El entrenamiento de la fuerza del core también ha demostrado su validez en el acondicionamiento físico de los jugadores de artes marciales. Objetivo: Este trabajo estudia los cambios cualitativos en el equilibrio de los atletas de artes marciales causados por la inserción del entrenamiento de resistencia del core. Métodos: Este artículo selecciona 24 jugadores de artes marciales por muestreo y los divide aleatoriamente en grupos de control y experimental. Los biomarcadores de los voluntarios se almacenaron y procesaron con métodos estadísticos para organizar y mostrar los datos. Resultados: Los grupos experimental y de control mostraron una alta significación estadística en cada índice tras la prueba (P<0,05). Los resultados muestran que los métodos utilizados en los grupos experimental y de control pueden mejorar eficazmente su rendimiento en los movimientos explosivos centrales y principales durante el ejercicio. Hubo cambios muy significativos en el pico muscular extensor en ambos grupos. El grupo experimental mostró una mejora más significativa que el grupo estándar (P<0,05). En comparación con el grupo de control, los picos flexores del grupo experimental mostraron una diferencia más significativa. En cambio, el grupo experimental mostró una mejora más notable que el grupo estándar (P<0,05). Conclusión: El ejercicio de resistencia del core puede promover eficazmente el equilibrio del centro de gravedad en los atletas de artes marciales. Nivel de evidencia II; Estudios terapéuticos - investigación de los resultados del tratamiento.

13.
Rev. bras. med. esporte ; 29: e2021_0013, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1387958

ABSTRACT

ABSTRACT Introduction Strong core stability and strength enable the trunk to transfer the maximum amount of torque to the terminal segments, which is conducive to improving athletic performance. Because sling training is a new core exercise method, its effect on trunk endurance relative to basketball performance has rarely been studied. Objective To investigate whether a core exercise program in a specific sports group can improve core and sports-specific performance. Methods A total of 40 college students majoring in basketball were randomly assigned to training and control groups. A standardized set of core endurance and basketball-specific performance tests were used to determine and assess the effects of sling training on trunk strength, endurance, and control. Results Flexor, extensor, and right and left lateral trunk flexor muscles endurance were significantly greater in the training group than in the control group, and the time to complete the layup obstacle course was shorter than in the control group at the end of the training program, p<0.01. No differences between the two groups were found in the penalty shot, the fixed position shot, or the vertical jump and reach at the end of the training program. Conclusions Sling exercises can improve the core endurance and strength of basketball players and increase the speed of lay-ups over obstructions. Level of evidence I; Randomized clinical trial.


RESUMEN Introducción La sólida estabilidad y fuerza del core permiten que el tronco transfiera el torque máximo a los segmentos terminales, lo que conduce a mejorar el rendimiento deportivo. Como método novedoso de ejercicio para el core, se ha estudiado poco el efecto del entrenamiento con ejercicios con sling sobre la resistencia del tronco en relación con el rendimiento en el baloncesto. Objetivo Investigar si un programa de ejercicios para el core en un grupo deportivo específico puede mejorar el rendimiento del core y específico del deporte. Métodos Un total de 40 estudiantes universitarios con especialización en baloncesto fueron asignados aleatoriamente a grupos de entrenamiento y de control. Se utilizó una serie estandarizada de pruebas de resistencia del core y rendimiento específico del baloncesto para determinar y evaluar los efectos de los ejercicios con sling en la fuerza, la resistencia y el control del tronco. Resultados La resistencia de los músculos flexores, extensores y flexores laterales derecho e izquierdo del tronco fue significativamente mayor en el grupo de entrenamiento en comparación con el grupo de control, y el tiempo para completar la prueba de tiro con obstáculos fue menor que el del grupo de control al final del programa de entrenamiento, p<0,01. No hubo diferencias entre los dos grupos en lo que respecta a: tiro libre, lanzamiento en posición fija y salto vertical y alcance al final del programa de entrenamiento. Conclusiones Los ejercicios con sling pueden mejorar la resistencia y la fuerza del core en jugadores de baloncesto y aumentar la velocidad de los tiros con dribling. Nivel de evidencia I; Ensayo clínico aleatorizado.


RESUMO Introdução A sólida estabilidade e a força do core permitem que o tronco transfira o torque máximo para os segmentos terminais, o que é propício para melhorar o desempenho atlético. Como um novo método de exercício para o core, o efeito do treinamento com sling na resistência do tronco com relação ao desempenho no basquete tem sido pouco estudado. Objetivo Investigar se um programa de exercícios para o core em um grupo esportivo específico pode melhorar o desempenho do core e específico do esporte. Métodos Um total de 40 estudantes universitários formados em basquete foram aleatoriamente designados para grupos de treinamento e controle. Uma série padronizada de testes de resistência do core e desempenho específico do basquete foi usada para determinar e avaliar os efeitos dos exercícios com sling na força, resistência e controle do tronco. Resultados A resistência dos músculos flexores, extensores e flexores laterais direito e esquerdo do tronco foi significativamente maior no grupo treinamento em comparação ao grupo controle e o tempo para concluir o teste de bandeja com obstáculos foi menor que o do grupo controle no final do programa de treinamento, p < 0,01. Não houve diferenças entre os dois grupos quanto ao lance livre, arremesso em posição fixa e salto vertical e alcance no final do programa de treinamento. Conclusões Os exercícios com sling podem melhorar a resistência e a força do core em jogadores de basquete e aumentar a velocidade das bandejas com drible. Nível de evidência I; Estudo clínico randomizado.

14.
MHSalud ; 19(2)dic. 2022.
Article in Spanish | LILACS, SaludCR | ID: biblio-1405527

ABSTRACT

Resumen El estudio tiene como propósito analizar la fiabilidad de la prueba de 8 lanzamientos de 3 diferentes variantes de lanzamientos de balonmano en estudiantado universitario. 33 varones, 20 ±1,9 años; peso 72,39±8,9 kg; altura 176,75 ±6,07 cm; IMC 23,14±2,3. Los sujetos participantes fueron evaluados en 2 sesiones separadas entre sí por un lapso de una semana. Ejecutaron lanzamientos hasta quedar registrados 8 mediciones en cada una de las pruebas, lanzamientos inespecíficos, en apoyo y en carrera con 3 pasos, se registró la velocidad de lanzamiento con un radar posterior a la portería. La fiabilidad del promedio de las puntuaciones del test de 8 medidas entre la primera sesión y la segunda con una prueba test-retest, se obtuvieron los siguientes resultados: en el lanzamiento inespecífico se obtuvo un ICC= (0,86) entre el 95% de confianza, un de CV= (7,43%) y un ES= (0,08). Para el lanzamiento con apoyo se obtuvo un ICC= (0,94) al 95 % de confianza, un de CV= (4,71 %) y un ES= (-0,09). Para el lanzamiento con carrera se obtuvo un ICC= (0,96) al 95 % de confianza, un de CV= (4,00 %) y un ES= (0,05). Este estudio ha demostrado que la prueba de 8 lanzamientos y las 3 variantes es una medida de rendimiento confiable y estable para estudiantes de nivel universitario sin experiencia en el balonmano, en relación con las variables del lanzamiento, las 3 fueron fiables, solo la variable inespecífica fue menor en comparación al lanzamiento con apoyo y con carrera.


Abstract This study aims to analyze the reliability of the test of 8 throws of 3 different variants of handball throws in university students. The participants were 33 males, 20 ± 1.9 years; weight 72.39 ± 8.9 kg; height 176.75 ± 6.07 cm; BMI 23.14 ± 2.3. They were evaluated in 2 sessions separated from each other by a period of one week. The participants executed throws until 8 measurements were recorded in each of the tests, unspecific throws, in support and in the race with 3 steps; the launch speed was recorded with a radar behind the goal. The reliability of the average of the test scores of 8 measurements between the first session and the second was measured with a test-retest test. The following results were obtained: in the nonspecific launch, an ICC= (0.86) was obtained between 95% of confidence, one of CV= (7.43%) and one ES = (0.08). For the toss with support, an ICC = (0.94) was obtained at 95% confidence, one of CV = (4.71%) and an ES = (-0.09). For the running throw, an ICC = (0.96) was obtained at 95% confidence, one of CV = (4.00%) and one ES = (0.05). This study has shown that the test of 8 throws and the 3 variants is a reliable and stable performance measure for university-level students without experience in handball; in relation to the throw variables, all 3 were reliable. Only the nonspecific variable was lower compared to the supported and running pitch.


Resumo O estudo tem como objetivo analisar a confiabilidade do teste de 8 arremessos de 3 variantes diferentes de arremessos de handebol em estudantes universitários. 33 homens, 20 ±1,9 anos; peso 72,39±8,9 kg; altura 176,75 ±6,07 cm; IMC 23,14±2,3. Os participantes foram testados em 2 sessões separadas por um lapso de 1 semana. Os participantes executaram arremessos até poder registrar 8 medições em cada um dos testes, arremessos não específicos, com apoio e correndo com 3 passos. A velocidade de arremesso foi registrada com um radar pós-gol. A confiabilidade da média dos resultados dos testes de 8 medições entre a primeira sessão e a segunda com um teste de retorno, deu os seguintes resultados: no teste de lançamento não específico, foi obtido um ICC= (0,86) com 95% de confiança, um CV= (7,43%) e um ES= (0,08). Para o lançamento apoiado obtivemos um ICC= (0,94) a 95% de confiança, um CV= (4,71%) e um ES= (-0,09). Para o arremesso de corrida obtivemos um ICC= (0,96) a 95% de confiança, um CV= (4,00%) e um ES= (0,05). Este estudo mostrou que o teste de 8 lances e as 3 variantes é uma medida de desempenho confiável e estável para estudantes universitários sem experiência em handebol. Em relação às variáveis de arremesso, todas as 3 foram confiáveis, apenas a variável não específica foi menor em comparação com o arremesso com suporte e com corrida.


Subject(s)
Humans , Male , Adult , Sports , Track and Field , Core Stability
15.
Aval. psicol ; 21(4): 371-382, out.-dez. 2022. ilus, graf, tab
Article in English | LILACS, INDEXPSI | ID: biblio-1447486

ABSTRACT

There is strong scientific evidence that intelligence remains stable from childhood to adulthood; however, no study has examined the generalizability of these findings for native Brazilian samples. Here we present a study carried out in 2002 and from 2014-2017 (average timespan of 15 years) in order to verify the stability of psychometric intelligence. A sample of 120 participants (mean age Time 1 = 10.0 yrs, mean age Time 2 = 23.6 yrs) was assessed using the Raven's Progressive Matrices and verbal subtests from the WISC-III and WAIS-III. The results indicated a moderate coefficient (around .50) for intelligence differential stability independent of the measurement administered. Regarding absolute stability, real cognitive gains were observed from Time 1 to Time 2, despite controlling the effect of the regression toward the mean. Finally, sex (female) and intelligence were statistically significant predictors of rapid educational progression. (AU)


Existe sólida evidência científica que a inteligência permanece estável desde a infância até a idade adulta, embora não existam estudos que verifique a generalidade desse pressuposto para amostra de nativos brasileiros. Aqui um estudo desenvolvido em 2002 e 2014/2017 (intervalo médio de 15 anos) que verifica a estabilidade da inteligência psicométrica é apresentado. Uma amostra de 120 participantes (Tempo 1 = 10,0 anos, Tempo 2 = 23,6 anos) foi avaliada com o uso das Matrizes Progressivas de Raven e as escalas verbais do WISC-III e do WAIS-III. Os resultados indicaram um coeficiente de estabilidade diferencial da inteligência moderado (aproximadamente 0,50), independentemente do tipo de medida administrada. Com relação à estabilidade absoluta, observaram-se ganhos cognitivos do Tempo 1 para o Tempo 2, apesar do controle do efeito da regressão à média. Finalmente, o sexo (feminino) e a inteligência foram os preditores estatisticamente significativos de uma rápida progressão educacional. (AU)


Existen fuertes evidencias científicas de que la inteligencia permanece estable desde la niñez hasta la edad adulta; sin embargo, no hay estudios que verifiquen la generalización de este supuesto para muestra de brasileños nativos. Aquí presentamos un estudio realizado en 2002 y de 2014 a 2017 (intervalo de tiempo promedio de 15 años) que comprueba la estabilidad de la inteligencia psicométrica. Se evaluó el desempeño de 120 participantes (Tiempo 1 = 10,0 años y Tiempo 2 = 23,6 años) con las Matrices Progresivas de Raven y escalas verbales del WISC-III y del WAIS-III. Los resultados indicaron un coeficiente de la estabilidad diferencial intelectual moderada (aproximadamente .50), independiente del tipo de medida administrada. En cuanto a la estabilidad absoluta, se observaron ganancias cognitivas del Tiempo 1 al Tiempo 2, a pesar de controlar el efecto de la regresión hacia la media. Por último, el sexo (femenino) y la inteligencia fueron predictores estadísticamente significativos de una rápida progresión educativa. (AU)


Subject(s)
Humans , Male , Female , Adult , Young Adult , Intelligence , Wechsler Scales , Regression Analysis , Longitudinal Studies , Correlation of Data , Sociodemographic Factors , Intelligence Tests
16.
Rev. colomb. ciencias quim. farm ; 51(3): 1049-1064, set.-dez. 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1431780

ABSTRACT

RESUMO Introdução: ao longo dos anos, a busca pela melhora do autocuidado estendeu-se às farmácias com manipulação, onde o cosmético pode ser manipulado de acordo com as preferências de cada indivíduo. Dessa forma, é necessário prover a estabilidade para cada produto manipulado, garantindo que um cosmético seguro e eficaz será dispensado. O ácido hialurônico é um ativo que tem se tornado popular devido à sua capacidade de realizar a manutenção da elasticidade da pele e exercer função hidratante, além de atuar na redução de linhas de expressão. Objetivo: analisar a qualidade de dermocosméticos manipulados a base de ácido hialurônico de diferentes farmácias com manipulação no município de Campo Grande-MS, através de análises laboratoriais físico-químicas e de rotulagem. Material e métodos: quatro amostras de creme-gel à base de ácido hialurônico 5% foram adquiridas em farmácias magistrais, e realizadas as seguintes análises de controle de qualidade: análise organoléptica, determinação de pH, densidade, teste de centrífuga, espalhabilidade e análise de rotulagem. Resultados: em relação às análises, os resultados obtidos foram satisfatórios. A análise organoléptica, o teste de centrifugação e de espalhabilidade se encontraram dentro dos padrões estipulados; porém, destaca-se o ensaio de densidade, em que duas amostras obtiveram valores abaixo do estipulado; e para a análise de rótulos, nenhum produto continha lista de componentes da formulação. Conclusão: ao final das análises, pode ser apontado que os produtos apresentaram desempenho satisfatório em grande parte dos testes propostos e são uma opção segura, de boa qualidade e custo acessível ao público.


SUMMARY Introduction: Over the years, the search for improving self-care has extended to compound pharmacy, where the cosmetic can be manipulated according to the preferences of each person. Thus, it is necessary to provide stability for each product handled, ensuring that a safe and effective cosmetic will be dispensed. Hyaluronic acid is an active that has become popular due to its ability to maintain skin elasticity and exert a moisturizing function, in addition to acting in the reduction of fine lines. Aim: To analyze the quality of cosmetics manipulated with the active ingredient of Hyaluronic Acid from different compound pharmacies in the city of Campo Grande-MS, through physical-chemical laboratory analysis and labeling. Material and methods: Four samples of 5% hyaluronic acid-based cream-gel were acquired from master pharmacies, and the following quality control analyzes were carried out: organoleptic analysis, pH determination, density, centrifuge test, spreadability and labeling analysis. Results: Regarding the analyses, the results obtained were satisfactory. The organoleptic analysis, the centrifugation test and the spreadability were within the stipulated standards; however, the density test stands out, in which two samples obtained results below the stipulated; and for label analysis, no product contained a list of formulation components. Conclusion: At the end of the analyses, it can be pointed out that the products presented satisfactory performance in most of the proposed tests and are a safe option, of good quality and accessible to the public.


RESUMEN Introducción: a lo largo de los años, la búsqueda por mejorar el autocuidado se ha extendido a las farmacias, donde los cosméticos pueden ser manipulados según las preferencias de cada individuo. Por lo tanto, es necesario proporcionar estabilidad a cada producto manipulado, asegurando que se dispensará un cosmético seguro y eficaz. El ácido hialurónico es un activo que se ha popularizado por su capacidad para mantener la elasticidad de la piel e hidratarla, además de actuar para reducir las líneas de expresión. Objetivo: analizar la calidad de los dermocosméticos manipulados a base de ácido hialurónico de diferentes farmacias en Campo Grande-MS, mediante análisis de laboratorio físico-químico y marcaje. Material y métodos: se adquirieron en farmacias magistrales cuatro muestras de crema-gel a base de ácido hialurónico al 5%, y se realizaron los siguientes análisis de control de calidad: análisis organoléptico, determinación de pH, densidad, prueba de centrifugación, untabilidad y análisis de marcaje. Resultados: en cuanto a los análisis, los resultados obtenidos fueron satisfactorios. Las pruebas de análisis organoléptico, centrifugado y untabilidad estuvieron dentro de los estándares estipulados, sin embargo, se destaca la prueba de densidad, en la que dos muestras obtuvieron valores por debajo del valor estipulado y para el análisis de etiquetas, ningún producto contenía una lista de componentes de la formulación. Conclusión: los productos se desempeñaron satisfactoriamente en la mayoría de las pruebas propuestas y son una opción segura, con buena calidad y su costo accesible al público.

17.
Arq. ciências saúde UNIPAR ; 26(3): 1044-1052, set-dez. 2022.
Article in Portuguese | LILACS | ID: biblio-1414341

ABSTRACT

As soluções volumétricas são rotineiramente utilizadas nos laboratórios, principalmente nos processos de síntese de produtos e nas análises quantitativas de matéria-prima e/ou produto acabado, entretanto poucos são os estudos que abordam a estabilidade destas soluções. Considerando que a qualidade das soluções volumétricas pode afetar os procedimentos de análises químicas e consequentemente induzir a erros, e ainda que, a Farmacopeia Brasileira (2010) não cita tempo máximo de utilização dessas soluções padronizadas, a avaliação da estabilidade das mesmas é importante. Sendo assim, o objetivo do trabalho foi avaliar a estabilidadede 10 soluções volumétricas, empregadas rotineiramente em laboratórios de análises químicas, com o intuito de estabelecer o período que essas soluções permanecem estáveis, isto é, sem sofrer alteração na concentração. As metodologias de preparo e padronização das soluções volumétricas seguiram os métodos descritos na Farmacopeia Brasileira (2010), sendo as mesmas padronizadas no momento do preparo e a cada 20 dias, por um período de 180 dias. As soluções contendo ácidos e bases, bem como as soluções de iodato de potássio e nitrato de prata, permaneceram constantes durante o período de análises. As soluções de EDTA, iodo, nitrito de sódio, permanganato de potássio e tiossulfato de sódio apresentaram estabilidade inferior a 180 dias, tornando necessária a realização de padronização periódica. As soluções volumétricas utilizadas nos laboratórios apresentam diferentes estabilidades, o que ressalta a importância da determinação do período que as mesmas se mantêmcom as concentrações estáveis, evitando possíveis alterações de resultados nas análises químicas.


Volumetric solutions are routinely used in laboratories, mainly in product synthesis processes and in quantitative analyzes of raw materials and/or finished products, however there are few studies that address the stability of these solutions. Considering that the quality of volumetric solutions can affect chemical analysis procedures and consequently induce errors, and even though the Brazilian Pharmacopoeia (2010) does not mention the maximum time for using these standardized solutions, the evaluation of their stability is important. Therefore, the aim of this work was to evaluate the stability of 10 volumetric solutions, routinely used in chemical analysis laboratories, in order to establish the period that these solutions remain stable without changing their concentrations. The methodologies for preparing and standardizing the volumetric solutions followed the methods described in the Brazilian Pharmacopoeia (2010), being standardized at the time of preparation and every 20 days, for a period of 180 days. Solutions containing acids and bases, as well as potassium iodate and silver nitrate solutions, were stable during the analysis period. The solutions of EDTA, iodine, sodium nitrite, potassium permanganate and sodium thiosulfate showed stability less than 180 days, making it necessary to carry out periodic standardization of these solutions. The volumetric solutions used in the laboratories have different stabilities, which highlights the importance of determining the period in which they remain stable, avoiding possible changes in results in chemical analyzes.


Las soluciones volumétricas se utilizan de forma rutinaria en los laboratorios, principalmente en los procesos de síntesis de productos y en el análisis cuantitativo de materias primas y/o productos acabados. Sin embargo, existen pocos estudios que aborden la estabilidad de estas soluciones. Considerando que la calidad de las soluciones volumétricas puede afectar los procedimientos de análisis químico y consecuentemente inducir a errores, y también que, la Farmacopea Brasileña (2010) no menciona el tiempo máximo de uso de estas soluciones estandarizadas, la evaluación de su estabilidad es importante. Así, el objetivo del trabajo fue evaluar la estabilidad de 10 soluciones volumétricas, utilizadas rutinariamente en los laboratorios de análisis químico, con el fin de establecer el período en que estas soluciones permanecen estables, es decir, sin sufrir alteraciones en la concentración. Las metodologías de preparación y estandarización de las soluciones volumétricas siguieron los métodos descritos en la Farmacopea Brasileña (2010), siendo las mismas estandarizadas en el momento de la preparación y cada 20 días, por un período de 180 días. Las soluciones que contienen ácidos y bases, así como las soluciones de yodato de potasio y nitrato de plata, permanecieron constantes durante el periodo de análisis. Las soluciones de EDTA, yodo, nitrito de sodio, permanganato de potasio y tiosulfato de sodio fueron estables durante menos de 180 días, por lo que fue necesario realizar estandarizaciones periódicas. Las soluciones volumétricas utilizadas en los laboratorios presentan diferentes estabilidades, lo que pone de manifiesto la importancia de determinar el periodo que permanecen con concentraciones estables, evitando posibles cambios en los resultados en los análisis químicos.


Subject(s)
Titrimetry , Laboratory Chemicals/analysis , Laboratories, Clinical , Periodicity , Potassium Permanganate/analysis , Reference Standards , Silver Nitrate/analysis , Sodium Nitrite/analysis , Thiosulfates/analysis , Brazilian Pharmacopeia , Iodates/analysis
18.
Rev. colomb. ciencias quim. farm ; 51(2): 539-556, mayo-ago. 2022. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1431777

ABSTRACT

RESUMEN Introducción: El ácido zoledrónico es un inhibidor de la resorción ósea que se utiliza en el tratamiento de la enfermedad de Paget, la prevención de la osteoporosis inducida por glucocorticoides y la osteoporosis en mujeres posmenopáusicas y hombres. Objetivo: Evaluar la estabilidad de un nuevo inyectable liofilizado de ácido zoledrónico 5 mg a través de los parámetros de calidad. Métodos: Se validó un método de HPLC con detector UV para determinar la estabilidad química de la formulación a través de la presencia de productos de degradación y la concentración del ácido zoledrónico en el producto terminado. También se midieron las características organolépticas, pH, esterilidad y endotoxinas bacterianas, partículas en inyectables y totalidad y transparencia de soluciones de este. Resultados: El método cromatográfico resultó satisfactorio para su empleo en la evaluación del producto terminado. Se elaboraron 3 lotes del inyectable de ácido zoledrónico 5 mg liofilizado, los cuales cumplieron con los límites de calidad establecidos durante los 6 meses (estabilidad acelerada) y hasta los 24 meses (vida útil).


SUMMARY Introduction: Zoledronic acid is an inhibitor of bone resorption used in the treatment of Paget's disease, the prevention of glucocorticoid-induced osteoporosis, osteoporosis in postmenopausal women and in men. Aim: To evaluate the stability of a new lyophilized injection of zoledronic acid 5 mg through the quality parameters. Methods: An HPLC method with UV detector was validated for the finished product and the chemical stability of the formulation was determined through the presence of degradation products and the concentration of zoledronic acid in the finished product. In addition, the organoleptic characteristics, pH, sterility and bacterial endotoxins, particles in injectables and totality and transparency of solutions were measured. Results: The chromatographic method was satisfactory for its use in the evaluation of the finished product. 3 batches of the lyophilized 5 mg zoledronic acid injection were made which met the quality limits established during 6 months (accelerated stability) and up to 24 months (shelf life).


RESUMO Introdução: O ácido zoledrónico é um inibidor da reabsorção óssea utilizado no tratamento da doença de Paget, na prevenção da osteoporose induzida por glico-corticóides e na osteoporose em mulheres e homens na pós-menopausa. Objetivo: Avaliar a estabilidade de um novo injetável liofilizado de ácido zoledrónico 5 mg por meio de parâmetros de qualidade. Métodos: Um método de HPLC com detector UV foi validado para determinar a estabilidade química da formulação através da presença de produtos de degradação e da concentração de ácido zoledrónico no produto acabado. Também foram medidas as características organolépticas, pH, esterilidade e endotoxinas bacterianas, partículas em injetáveis e totalidade e transparência de suas soluções. Resultados: O método cromatográfico foi satisfatório para sua utilização na avaliação do produto acabado. Foram produzidos três lotes de injeção de ácido zoledrónico liofilizado de 5 mg, que atenderam aos limites de qualidade estabelecidos para 6 meses (estabilidade acelerada) e até 24 meses (prazo de validade).

19.
Rev. inf. cient ; 101(1)feb. 2022.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1409514

ABSTRACT

RESUMEN Introducción: La calidad de la atención médica se relaciona directamente con el clima laboral adecuado y la satisfacción del personal de la salud. Con la aparición de la COVID-19 el clima laboral en las instituciones de salud se vio violentado. Objetivo: Identificar los factores que influyen en el clima laboral de las instituciones de salud pública y privadas de Santo Domingo de los Tsáchilas, Ecuador, durante el periodo junio-agosto de 2021. Método: Estudio con enfoque cuantitativo de alcance correlacional y diseño transeccional, en 349 trabajadores de la salud, a los que se les aplicó un cuestionario de 25 preguntas que midieron factores, como: riesgo al contagio, jornada laboral, recursos médicos y estabilidad laboral. Los resultados del estudio fueron analizados estadísticamente a través de SPPS 20 y AMOS 24, con el desarrollo anterior de alfa de Cronbach. Resultados: El 94 % de los participantes consideró como inadecuado el clima laboral de sus instituciones, mientras que el 6 % manifestó que no. Predominaron las féminas y los de 22-35 años. Todas las variables del modelo hipotetizado superaron el 0,70 y el alfa de Cronbach total alcanzó un 0,728; el modelo hipotetizado cumplió con la validez convergente y discriminante de las variables. El riesgo de contagio arrojó un valor de β=0,148, mientras que la jornada laboral resultó con β=0,010, recursos médicos β=0,006 y estabilidad laboral β=0,007. Conclusiones: Los hallazgos determinaron que el riesgo al contagio es el factor más influyente en el clima laboral de las instituciones objeto de estudio durante los inicios de la pandemia por la COVID-19.


ABSTRACT Introduction: The quality of medical care is directly related to the appropriate work environment and the satisfaction of the health staff. With the appearance of COVID-19, the work environment in health institutions has worsened. Objective: To identify the factors that influence the work environment of the public and private health institutions of Santo Domingo de los Tsáchilas, Ecuador, during the period June-August 2021. Method: Implementation of a study with a quantitative approach of correlational scope and transectional design in 349 health workers, to whom a 25-questions questionnaire was applied, that measured factors such as: contagion risk, working hours, medical resources and job stability. The results of the study were statistically analyzed through SPPS 20 and AMOS 24, with the previous development of Cronbach's alpha. Results: 94% of the participants considered the work environment of their institutions as inappropriate, while 6% said they did not. Females, and ages ranging between 22-35 years predominated. All the variables of the hypothesized model exceeded 0.70 and the total Cronbach's alpha reached 0.728; the hypothesized model met the convergent and discriminant validity of the variables. The risk of contagion yielded a value of β=0.148, while the working day resulted with β=0.010, medical resources β=0.006 and job stability β=0.007. Conclusions: The findings determined that the risk of contagion is the most influential factor in the work environment of the institutions under study during the beginning of the COVID-19 pandemic.


RESUMO Introdução: A qualidade da assistência médica está diretamente relacionada ao ambiente de trabalho adequado e à satisfação do pessoal de saúde. Com o surgimento da COVID-19, o ambiente de trabalho nas instituições de saúde foi violado. Objetivo: Identificar os fatores que influenciam o ambiente de trabalho das instituições públicas e privadas de saúde de Santo Domingo de los Tsáchilas, Equador, no período de junho a agosto de 2021. Método: Estudo com abordagem quantitativa de escopo correlacional e delineamento transversal, em 349 trabalhadores de saúde, aos quais foi aplicado um questionário de 25 questões que mediam fatores como: risco de contágio, jornada de trabalho, recursos médicos e estabilidade no emprego. Os resultados do estudo foram analisados estatisticamente por meio do SPPS 20 e AMOS 24, com o desenvolvimento prévio do alfa de Cronbach. Resultados: 94% dos participantes consideraram o ambiente de trabalho de suas instituições inadequado, enquanto 6% disseram que não. Predominaram mulheres e pessoas de 22 a 35 anos. Todas as variáveis do modelo hipotético ultrapassaram 0,70 e o alfa de Cronbach total atingiu 0,728; o modelo hipotético atendeu à validade convergente e discriminante das variáveis. O risco de contágio resultou em β=0,148, enquanto a jornada de trabalho resultou em β=0,010, recursos médicos β=0,006 e estabilidade no trabalho β=0,007. Conclusões: Os achados determinaram que o risco de contágio é o fator mais influente no ambiente de trabalho das instituições em estudo durante o início da pandemia do COVID-19.

20.
Braz. j. biol ; 82: e256502, 2022. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1364493

ABSTRACT

Tagetes genus of Composite family consider one of the most favorite floriculture plants. Therefore, of particular interest examine the salt tolerance of this bedding and coloring agent plant. In this research, was report the role of glycinebetaine (GB) in attenuating the adverse impacts of salt stress in African marigold plant, along with their anti-oxidative capacities and biochemical attributes. The salt stressed African marigold (100 and 150 mM NaCl) was treated with GB at 200 mM, beside untreated control plants. According to the obtained results, the growth characters were negatively in salt stressed plants but a mitigate impact of GB were observed in this respect. Obviously, the morphological as well as some physiological characters were reduced with salinity treatments while GB treatment reverses these effects. Overall, the alleviate impact of GB on the negative impact of salt stress was enhanced through improving total phenolic and antioxidant enzyme activity. Further, it is concluded that GB concentration induces the activities of antioxidative enzymes which scavenged ROS increased under saline conditions.


O Tagetes, da família Composite, é um dos gêneros mais apreciados de plantas de floricultura. Portanto, é de particular interesse examinar a tolerância ao sal desta planta de substrato e corante. Nesta pesquisa, foi relatado o papel da glicinebetaína (GB) na atenuação dos impactos adversos do estresse salino na calêndula africana, juntamente com suas capacidades antioxidantes e atributos bioquímicos. A calêndula africana estressada com sal (NaCl 100 e 150 mM) foi tratada com GB a 200 mM, ao lado de plantas de controle não tratadas. De acordo com os resultados obtidos, os caracteres de crescimento foram negativos em plantas estressadas por sal, mas um impacto mitigado de GB foi observado neste aspecto. Obviamente, os caracteres morfológicos e fisiológicos foram reduzidos com os tratamentos de salinidade, enquanto o tratamento com GB reverteu esses efeitos. No geral, o impacto de alívio do GB no impacto negativo do estresse salino foi aprimorado através da melhoria da atividade das enzimas fenólicas e antioxidantes totais. Além disso, conclui-se que a concentração de GB induz as atividades de enzimas antioxidantes que sequestraram ROS aumentadas em condições salinas.


Subject(s)
Calendula/growth & development , Salinity , Salt Tolerance , Salt Stress , Antioxidants
SELECTION OF CITATIONS
SEARCH DETAIL